Blood dewatering system. Rated for up to 5-7 gpm (1000-1500 litres/hour)
ANCO 305 Blood Coagulation and Dewatering System
- Design capacity: 1000-1500 litres/hour of fresh whole blood
- Heavy-duty stainless steel construction
- Designed to allow for solids (i.e. chicken heads)
- Vertical design (for minimum space requirements)
- Process piping connection
- Low HP design (2.5 HP)
- Reduces moisture of properly coagulated blood to 65-70%
- Includes stainless steel vapour connection for reduced plant emissions
ANCO Blood System PLC and Valve Package
- Low voltage panel with PLC and HMI to allow the system to run in "auto" mode
- Temperature control system and thermocouples
- Steam pilot pressure regulator valve
- ANCO steam feed manual valve package and miscellaneous gauges and indicators
ANCO 228 Blood Pump
- Positive displacement blood metering pump
- Chrome-plated alloy steel rotor
- 3" inlet, 2½" outlet
- Capacity: 2 gallons; 25 gallons maximum
- 2 HP (VFD by client) TEFC drive
- Blood pump with base
Project Services & Scope of Supply:
A) Design and drafting related to the attached drawing list
B) Project management for the equipment design and layout
C) Equipment procurement
D) Two (2) sets of operation and maintenance manuals
E) Electrical equipment specifications for equipment supplied by ANCO
F) General drawing package to include one or more of the following drawings:
* Electrical Layout, Power Wiring, Control Panel and Control Wiring
* Elevations, Roof and Wall Openings
* Process Flow Analysis for ANCO supplied equipment only
* Sections & Details as required
* Foundation layouts; suggested placement of ANCO supplied equipment
We use cookies to improve your experience. Privacy Policy.