Used regenerative thermal oxidiser constructed by Ceco in 2006.
- Original design capacity was 83,070 SCFM with five chambers, each having a cross-sectional area of 12.54 square metres (or 136.5 square feet).
- Current capacity is approximately 40,000 SCFM and comes with three stainless steel chambers.
- System includes MCCs, VFD, ducting, main process induced fan (400 HP, 1185 rpm, 480 V, 60 Hz), and inlet/outlet manifolds.
- Requires control panel, dampers, gas train and burners, and stack.
- RTO can be refurbished and retrofitted to your design by the original design company for an additional payment.