Used 0.8 MW MWM CHP power plant including two engines rated at 400 kW, fuelled by biogas and housed in soundproof containers. Manufactured in 2011 and still operating two days per month. 19,442 and 19,633 hours of use recorded by February 2024. Equipment list includes:
- Two MWM TCG 2016 V08 C engines rated 400 kW electrical output, 395 kW thermal output ± 8%, electrical efficiency 42.8%, thermal efficiency 42.1%. Gas train, gas mixer, generator, voltage stabiliser, power factor controller, coupling, control unit and switchboard.
- Exhaust silencer.
- CHP power cabinet.
- Heat exchanger cabinet, heat extraction/hydraulic system, plate heat exchanger, surge tank.
- Electrical circulation pump for combustion engine.
- Mixture cooling.
- Exhaust gas heat exchanger.
- Soundproofed container, 65 dB(A) at 10 m, emergency cooler, engine control system.
Each 400 kW engine may be available separately; more information on request.