(2) Unused nitrogen gas generating air separation units with capacity 200 mTPD combined. Each system was designed to produce a flow rate of 3,334 Nm3/hour (100 mTPD) at 115 PSIG and 0 degrees Celsius. The nitrogen produced is of the highest purity, meeting industry standards as follows:
- Oxygen (O2): maximum 3 ppm v/v
- Moisture (H20): maximum 3 ppm v/v
- Total hydrocarbons (THC): Maximum 1 ppm
- Carbon dioxide (CO2): Maximum 0.5 ppm v/v
- Carbon monoxide (CO): Less than 1.5 ppm v/v (when incoming air CO<450 ppb +/-50 ppb v/v)
- Hydrogen: (H2): Less than 1.0 ppm v/v (when incoming air H2<280 ppb v/v +/- 20 ppb)
Main equipment includes:
a)
- Nitrogen Generator, TGN 3700
- Assembly, Coldbox, Module, Nitrogen Generator
- Assembly, Upper Skid Air Treatment Module, Nitrogen Generator, TGN3700
- Assembly, Lower Skid Air Treatment Module, Nitrogen Generator, TGN 3700
- Turboexpander Proxy Assembly
b) Air Handling and Treatment:
- Main Air Compressors
- Adsorber for TGN 3700
- Ambient Vaporizers
- Alumina, Activated, Active Bed Support (ABS) Media (For both plants)
c) Cooling and Condensation Systems:
- Cooling Towers/Condensers
- Chiller Module
- Cooling Water Pump Skid
d) Cryogenic and Storage Systems:
- Cryogenic tanks
e) Electrical and Control Systems:
- Compressors Starters
- Motor Control Center
- Control System
- Assembly, Analyzer Rack, Single Bay, TGN 3700
- Online Analyzer Panel
More information on request.