Used hydrogen plant with capacity 708 Nm3/hour (25000 SCFH) of hydrogen with purity 99.99%. Made in 1977 by Hydro Chem and shut down in 2015.
Plant includes the following major equipment:
- Reformer designed with (8) tubes, (6) installed and (2) available.
- (4) PSA columns.
- Waste heat boiler provides approximately 1 ton/hour of steam at 16 barg (230 psig).
- High pressure gas compressor made by Gardner Denver with 45 kW (60 HP) drive.
- Siemens PLC & control panel, valves, pipes.
Utility requirements:
- Feed & Fuel Gas 1.74 MMBTU/Hour.
- Power 32KW.
- Steam 2100 lbs/hour.
- Water 425 gpm.
- Plot area 46 x 66 feet.