26,000 kW 50 Hz Kawasaki Cogeneration Plant

Cogeneration Power Plants
Stock #:
RG2194
Used 26 MW, 50 Hz cogeneration plant made in 2010. Major equipment includes: - Kawasaki GPB180D/L20A gas turbine (GT1). Gases flowrate 59.8kg/s, nominal electrical power 17.613 MWe, gases outlet temperature 541 degree Celsius, 9420 RPM. - Brush DG 165Z-04 generator for GT1. Nominal power 21,066 kVA, 1500 RPM, 50 Hz. - Energest water tube heat recovery boiler (CR1). Steam pressure 21 bar (r), steam temperature 304 degrees Celsius, steam production (without post combustion or fresh air) 33.95 tons/hour, steam production (with post combustion but without fresh air) 39.20 tons/hour, steam production (with post combustion and fresh air) 49.90 tons/hour, gas temperature after last heat 160-165 degrees Celsius. Post combustion fuel natural gas. - Kawasaki GPB80D/M7A gas turbine (GT2). Gases flowrate 26.91 kg/s, nominal electrical power 7.23 MWe, gases outlet temperature 550 degree Celcius, 13790 rpm. - Leroy Somer LSA 56 BMBL 13/4P generator for GT2. Nominal power 9281 kVA, 1500 RPM, 50 Hz. - Energest water tube heat recovery boiler (CR2). Steam pressure 21 bar, steam temperature 304 degrees Celsius, steam production (without post combustion or fresh air) 14.3 tons/hour, steam production (with post combustion but without fresh air) 18.7 tons/hour, steam production (with post combustion and fresh air) 49.8 tons/hour, gas temperature 149-160 degress Celsius. Post combustion fuel natural gas.